PLCcore-iMX35

PLCcore-iMX35是一款强大的软-PLC,可作为基板用于你自己的HMI-设备。它最少化必需外设连接性可简化特定应用基板的设计。因为有各种本地输入和输出以及板载支持的通讯接口,PLCcore-iMX35可通过多个网络接口以常用方式连接到它的外围环境。附加应用领域包括能够执行独立的Linux应用程序,并行于PLC运行时系统。

使PLC用作即插即用核心模块,具有小尺寸,能够极大减少用户特定控制开发的时间和成本。PLCcore-iMX35也特别适用于用作定制HMI设备的基础部件和智能网络节点用于分散处理过程信号 (CANopen和UDP)。

模块特点

PLCcore Firmware: IEC61131-3
PLCcore-iMX35: IEC61131-3 runtime kernel pre-installed, Shared process image, CiA302/314 compliant CANopen manager, Customizable I/O driver, Program download via Ethernet
PLCcore-iMX35 HMI: IEC61131-3 runtime kernel pre-installed with SpiderControl MicroBrowser GUI, Shared process image, CiA302/314 compliant CANopen manager, Customizable I/O driver, Program download via Ethernet
Controller: Freescale i.MX357 with ARM11 Core
System Clock: 532 MHz
RAM: 128MiB DDR2-SDRAM
FLASH: 128MiB NOR
On-board Peripherals: DMA, MMU, hardware watchdog, temperature sensor, RTC
Fast Ethernet: 1x 10/100Mbps, on-board PHY
CAN: 2
UART: 3
USB: 1x USB 2.0, 12Mbps full-speed
1x OTG
SPI/I2C: 1/1
Mass storage: MMC/SD-card signals on board-to-board connector
LCD: TFT-LCD interface brought out via CMOS , resolution 800x600 max. 24bit
Others: S/PDIF
Operating Conditions: Temperature: -40°C…+85°C
Humidity: 10-90% RH, non-condensing
Power Supply: 3.3V +/- 5%, 0.3A max.
Dimensions/Weight: 78 x 54 x 7,2 (L x W x H in mm), 20g
Board-to-board connector: 2x 2x 50 pin header socket, 1.27 mm pitch
Available on board-to-board connector: 2x CAN, 3x ASC, 2x USB, I²C, SPI, 2x SD-card, 18x GPIO, Ethernet, TFT-CMOS, PWM/DIO, Timer/Counter/DIO
RoHS compliant: yes
Operating System: Linux, QT framework optionally
Integrated Development Environment (IDE): IEC 61131-3 IDE (OpenPCS) with SYS TEC vendor extensions for PLC programming,
Pre-integrated Eclipse-based IDE with GNU C/C++ tool chain, source- and assembly-level debugger

 

说明

The PLCcore-iMX35 is an IEC 61131-3-programmable Soft-PLC with integrated target visualization. That's why it represents itself as the ideal base component for designing user specific HMI devices. The PLCcore-iMX35 provides 16 digital inputs and 10 digital outputs for direct connection to local peripherals. Due to the various communication interfaces such as Ethernet, CAN and serial interfaces, furthermore remote extension equipment can be connected. The PLC Runtime System supports data exchange by several function block libraries for CANopen, CAN Layer 2, UDP and SIO.

The PLCcore-iMX35 allows for direct connection of CMOS and LVDS displays. The integrated target visualization is based on the SpiderControl MicroBrowser and supports touchscreen, scroll wheel as well as matrix und USB keyboards as input devices. The adjustment of the keyboard layout can be made by using function blocks of the PLC.

Only a minimal peripheral wiring is necessary to apply the PLCcore-iMX35 on an application-specific baseboard. That's why devices based on this core module can be designed very cost-efficiently. The Linux BSP, which is provided in source code, allows for application of user-specific peripheral components. Furthermore, the configuration of start scripts and kernel-internal drivers can be reduced in a manner, that boot-up time spans less than 3 seconds from power-on until displaying the process visualization can be reached.

Additional arbitrary Linux applications can be executed on the PLCcore-iMX35 in parallel to the PLC Runtime System. For data exchange between a Linux application and the PLC Runtime System, inter process communication mechanisms such as FIFOs or mutex-protected Shared Memory are available. Furthermore, the PLC has full access to the file system. On demand, data can be written to or read from any mounted media.

The PLCcore-iMX35 is equipped with an on-board Flash of 128 MiB, whereby a memory range of 90 MiB is freely available as mass storage for the PLC program, for visualization data and for process data. Due to the usage of UBIFS (Unsorted Block Image File System) with active journaling, the file system keeps in a consistent state even in case of an unexpected power supply break down.

The PLC Runtime System allows for usage of both CAN interfaces as CANopen-Manager. The integrated CAN controllers are equipped with a receive FIFO. That's why even applications with permanent CAN bus load up to 70 percent can be implemented without any packet loss of CAN messages.

The optional web visualization supports monitoring, servicing and diagnostic system analysis from remote PCs, even from far.

订货信息

货号 说明
3390065 PLCcore-iMX35
incl. OpenPCS, Linux, program download via Ethernet
3390075 PLCcore-iMX35 - HMI
incl. OpenPCS, Linux, SpiderControl Target Visualization, program download via Ethernet
3393000 License Spidercontrol Web Visualization

下载

OpenPCS IEC 61131-3 programming system
Version V6.7.4 RV1.00 - english
70 MB
SYS TEC - specific Extensions for OpenPCS / IEC 61131-3
Version 6.7.4 RV1.00 - english
27 MB

如果你需要上面的资料请通过support@hj-baofeng.net联系我们。

 

相关文档

模块上系统 - ECUcore概述 CANopen Tool Chain - Product Flyer
PLCcore概念 - 白皮书 CANopen Tool Chain - Product Flyer
PLCcore-iMX35 - 系统手册 (EN) CANopen Tool Chain - Product Flyer
ECUcore-iMX35 - 硬件手册 (EN) CANopen Tool Chain - Product Flyer

相关产品

开发包PLCcore-iMX35 » 
ECUcore-iMX35 » 
开发包ECUcore-iMX35 »

欢迎通过sales@hj-baofeng.net联系我们。

 

虹科 > 自动化 > 德国思泰电子 我们是CiA会员
工业通讯
CAN和CANopen源代码和工具链
接口和网关

Ethernet POWERLINK源代码
模块上系统
开发包
核心模块
   按应用分类

   按架构分类

   操作系统层可编程模块

   IEC 61131-3可编程模块
   VHDL可编程模块
自动化部件
IEC 61131-3 PLC
CANopen I/O模块

开发和配置工具

OEM设计包
解决方案
服务项目
技术支持
新闻和活动

初级和高级培训课程

其它公司的相关产品
PEAK- System
Lawicel
更多


扫一扫加微信


关于虹科
:虹科积极进取,不断探索科技新领域。最优秀的员工和最好的技术能够接受最困难的挑战。为您找到最佳解决方案。虹科靠口碑赢得客户。

Email 博客 论坛 点击发送消息给我 

广州:020-3874 3032 | 上海:021-6728 3703 | 北京:010-5781 5068 | 西安:029-8187 3816

sales@hj-baofeng.net | 广州虹科电子科技有限公司 | 版权所有 | 广州市科学城神舟路18号润慧科技园C栋6层    

友情链接: