Included accessories:
Traceable calibration certificate from the manufacturer, instruction manual. Calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
Example of calibration certificate.
Included is also communication cable for RS232, length 2 meters, free Windows program. Free program is available to dowload anytime. Program enables to control all logger functions and view and print the record in numerical format.
Optional accessories:
Please order required input modules or other accessories.
|
SWR006 |
Optional software for Windows - comfort graphic environment data acquisition, including online graph, automatic data download, remote Display mode on Internet-Ethernet network, storing data on the network, administration of users and passwords and many others .. |
Accessories for data logger mounting |
|
MP013 |
Universal metal wall holders for data logger wall mounting. Package contains a pair of holders and 4 screws. |
|
MP012 |
Holder for data logger mounting to DIN 35mm rail. Package contains the holder and 6 screws. |
Power supplies |
|
A1759 |
Universal ac/dc adapter 230V-50Hz/21Vdc/1A. |
|
A1940 |
Universal ac/dc adapter 230V-50Hz/24Vdc/1A/24W for socket plug-in, switch-mode. |
|
A5948 |
Power supply 230V-50Hz/24Vdc/2,5A for DIN rail 35mm, dual terminals 24Vdc, switch-mode, including DIN rail of 100mm length. |
Backup power supplies |
|
A6963
power supply
A7963
battery |
Backup power supply A6963, model MINI-DC-UPS/24DC/2 with batery A7963, model MINI-BAT/24DC/1.3AH, manufacturer Phoenix Contact.
Power supply is designed for mounting to 35mm DIN rail in data logger case MP033 and MP034.
It contains two modules - UPS and battery.
Included is a DIN rail for mounting to the case. Power supply is delivered uninstalled in original manufacturer packaging.
Backup power supply is able to supply data logger system with 200 mA consumption at least 3 hours, data logger system with 500 mA consumption at least 2 hours, data logger system with 1A consumption at least one hour.
Discharged accumulators are recharged to full capacity in approximately 3 hours.
System enables to inform user on switch-over to battery operation.
More details are in Manual Appendixes.
For mounting to MP033 or MP034 case please order: 1pc A6963, 1pc A7963, 1pc MP035 rail. |
|
MP035 |
DIN rail 35mm of 226mm length with screws for mounting of A6963 power supply with A7963 batery to MP033 or MP034 case. |
|
A6966
power supply
A7966
battery |
Backup power supply A6966, model AWZ224, manufacturer Pulsar sp.j., Poland.
To this power supply it is necessary to buy two lead accumulators A7966 12V/7Ah in hermetical maintenance-free type of construction, e.g. type ELNIKA 12V/7.2Ah.
Power supply is designed for mounting to vertical inflammable wall with sufficient air flow. Its protection rate is IP20. It is not designed for mounting to closed switchboard. This backup power supply is able to supply data logger with transmitters of current consumption 200mA for approximately 35 hours. Discharged accumulators are recharged to full capacity in approximately 14 hours.
System enables to inform user on switch-over to battery operation.
More details are in Manual Appendixes.
Please order: 1pc A6966, 2pcs A7966. |
Optional internal equipment |
|
MP025 |
Built-in LAN interface for online data logger connection to Ethernet (Internet) network. Communication via: SNMP, SOAP, www pages. In case of limits exceeding alarm is activated and warning e-mail or SNMP trap are sent to specified addresses. |
|
MP024 |
Built-in independent SMS port for GSM modem connection for SMS reception and sending. Enables to receive information from data logger by means of SMS messages - actual values, alarms, memory occupation and others - as a response to SMS query from user or in case of alarm creation at data logger.
Not necessary, if data logger is connected to the PC via GSM modem. |
External communication converters |
|
MP021 |
Converter RS485/RS232 for serial port COMx at the PC side, including ac/dc adapter and terminator T485. |
|
MP022 |
Converter USB/RS485 for USB port at the PC side, including terminator T485. Powered from computer USB interface. |
|
MP023 |
Converter Ethernet/RS485 ncluding ac/dc adapter and terminator T485. Designed for several data loggers conencted via RS485 network for connection to the computer via Ethernet. |
Accessories connectable to ALARM OUT output |
|
MP026 |
External audio indication unit. Enables to signal alarm state acoustically at the location up to 50m from data logger. Audio unit is connected to data logger by a cable (not included). |
|
MP002 |
Telephone voice dialer for alarm reporting, ac/dc adapter included. Enables in ALARM OUT output activity to send voice report to selected telephone numbers. Voice dialer is connected to land line. |
Output relays module |
|
MP018 |
Output relays module with interconnection cable. It contains 16 mains relays 250V/8A with switching-over contacts. Each relay can be controlled based on alarm creation at different input channels accordingly to setting of user program. Any relay can be assigned to any alarm at any input. Output relays are designed for external devices control (switching of heating, cooling, ventilation, distant alarm etc.). It is necessary to order connection cable to data logger MP017, optionally other accessories. |
|
MP017 |
Connection cable for terminal with display and output relays module - cable length approximately 60cm.
Longer cable lengths available - maximum 2m for relay module, maximum 50m for the terminal with display. |
|
MP013 |
Universal metal wall holders for data logger wall mounting. Package contains a pair of holders and 4 screws. |
|
MP019 |
Holder for relay module mounting to DIN 35mm rail. Package contains the holder and 6 plastic rivets. |
|
MP020 |
DIN rail for relay module with elevated consoles for mounting to the MP033, MP034 case. Rail enables to raise the relay module enables to lead cables to data logger under the module. |
Terminals with display |
|
MP016 |
Terminal with dual line alphanumerical LCD and control buttons and 32 alarm LEDs - for panel mounting or mounting to a case lid. Identical functions as built-in terminal of MS5D data logger. It is possible to build in with IP54 protection. Maximum cable length to data logger 50m. It is necessary to order the MP017 connection cable to data logger. |
|
MP017 |
Connection cable for terminal with display and output relays module - cable length approximately 60cm.
Longer cable lengths available - maximum 2m for relay module, maximum 50m for the terminal with display. |
|
MP017-5 |
Connection cable for terminal with display - cable length 5m. |
|
MP017-10 |
Connection cable for terminal with display - cable length 10m. |
|
MP032 |
External terminal with dual line alphanumerical LCD, control buttons, 32 alarm LEDs and audio alarm indication. Built in a IP54 protection case, including 2m cable with covered terminals. Identical functions as built-in terminal of MS5D data logger. Maximum cable length to data logger 50m. |
Covers, cables and other accessories |
|
MP027 |
Covers of data logger terminals (pair). Designed for aesthetic covering of cables connected to terminals and connectors. Magnetic fixing to data logger. |
|
MP007 |
USB connection cable A-B, 1,8m.
Standard computer cable. |
|
MP030 |
RS232 connector with terminals for RS232 interface connection by means of terminals, not by D-Sub connector. |
|
MP031 |
Screwdriver for easy connection of cables to WAGO terminals. |
Assemblies in case with higher IP protection |
|
MP033 |
Case with IP65 protection with wall holders and data logger holders - no cutout in the lid.
Dimensions 270 x 570 x 140 mm. |
|
MP034 |
Data logger MS5 in IP54 protection case with connected terminal with display built in the lid.
Dimensions 270 x 570 x 140 mm. |
Connectable sensors and probes |
|
Interior temperature, humidity, pressure transmitters |
Interior temperature, humidity, barometric pressure transmitters
outputs 4-20mA, RS485 |
|
Industrial temperature, humidity, pressure transmitters |
Industrial temperature, humidity, barometric pressure transmitters
outputs 4-20mA, RS485 |
|
Pt1000 probes |
temperature probes with Pt1000/3850ppm sensor without connector - probe marking is followed by symbol /0 |
|
K thermocouple probes |
temperature probes with K thermocouple NiCr-Ni without connector - probe marking is followed by symbol /0 |
资料下载:
配置和订购单:
电子表格,易于选择监测系统和附件。
填写表格后,请以 e-mail 附件的形式发送给我们。
运行配置和订购单>>>
回到 MS5数据记录仪>>>
|